AE160AB Crack injection epoxy

Crack injection for re-inforcing
wall
column
beam
floor
pre-cast slab
tunnel
tank,ware house, barn
retard wall
dam
   
chimney

water-tight
porous floor
porous wall

gapping
tile
floor slab

 
  • non shrinkage- no crack during curing
  • low/high pressure injecting
  • liquidity- tiny gap
  • ready use pack
  • high tensile strength
  • high viscidity strength
  • water-tight, durable, anti-corrosion of rebar

 
A : B = 2 : 1 (weight)

 
1. Pour hardener into resin.   2. Mix thoroughly until light-brown color appearing.
 

 
  1. remove all dirt, oil, grease from surface by brushing or blowing
  2. locating the nipples distance between should be equil to depth of crack。
  3. paste AE111 adhesive on nipples
  4. locating pin must be position in crack
  5. glue the nipple on concrete surface firmly
  6. seal all crack by AE111AB
  7. inject the mixed AE160AB into crack by high/low pressure pumping system
  8. grinding off all sealing material and maintain the surface smooth

 
  1. use up before pot-life.
  2. wear protect gloves.
  3. self life one year(15℃--25℃ storage).
  4. solvent to clean.

 
density  

1~1.1kg/L

operation time   20 120mins
viscosity 20

400~500cps

compressive strength       7days after    600kg/c㎡
tensile strength   7days after 200kg/c㎡
bending strength 7days after 400kg/c㎡
bonding strength 7days after

120kg/c㎡


 