AEG Chemical anchor system
  AEG series provide you more professional anchor series
AEG M8~M30 chemical anchor medicine tube
AES M8~M30 zinc-coated screw pole
   
Features:
  • Big anti-pulls strengthen, special for heavy installation and anchor.
  • Fit together with construction ,as if pre-buried , good anti-vibration ,no morals and custom of hole ,no aging ,no acidity ,drill a hole according to your need, no dicey factor of pre-buried.
  • The influences of side distance and interval distance is small, which is just fitted to use for curtain wall.
  • Also can be used for hang panel, hang system, stone materials and wet panel, the scope of application is extensive.
  • Because of use one to one ,it is easy to control the quality of construction.
Products material:
  • AES --zinc-coated screw pole,IS0898T1 5.8
  • AESR --stainless screw pole,SUS304
  • AEG--chemical anchor medicine tube, Epoxy Acrylate,curing agent,quartz and glass tube
   
Installation for base platform
Installation by curtain wall
Foundation screw bolt
Anchor by steel slab
   
Setting details:
Anchor size M8 M10 M12 M16 M20 M24 M30
DB(m/m) Drill bit diameter 10 12 14 18 25 28 35
T(m/m) Embedment depth 80 90 110 125 170 210 280
Smax(m/m) Object thickness 14 21 28 38 48 54 70
L(m/m) Length of Anchor 110 130 160 190 240 290 380
D(㎝) Min. thickness of base material 13 14 16 17.5 22 26 33
Mp(Nm)Max. tweak moment 10 20 40 80 150 200 400
ar (㎝)Std. distance to edge 10 11 13.5 15.5 21 26 35
a (㎝)Std. distance 20 22 27 31 42 52 70
Reaction time:
base material temperature(℃) >20℃ 10~20℃ 0~10℃ -5~0℃
hardening time(Min) 10 20 60 5hrs
 
Mechanical properties (KN):
Anchor size M8 M10 M12 M16 M20 M24 M30
Allowable force *Fzul(KN)
(0℃ to 90℃)
Concrete degree B15 2.8 4.9 7.0 10.5 18.9 25.5
  Concrete degree B25 4.0 7.0 10 15.0 27.0 37.0
Mb(NM) Max. safe working moment Zinc-coated screw pole 7.8 15.6 27.3 69.4 135 234
  Stainless screw pole 9.4 18.7 32.8 83.3 162 156
Destruction tension Fu(KN) Concrete degree B25 18.9 28.6 40.6 80.8 112 131.8
   
Installation procedures:
 

Drill a hole according to technical

Clean up the hole with steel brush and blow air pump

Put the medicine tube (round end) into the hole

 

  Mix medicine even with electrical drill driving the pole

It's available for load use after harden time

 